EasyManua.ls Logo

R&S ZNA67 - Page 941

R&S ZNA67
1709 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Command reference
R&S
®
ZNA
941User Manual 1178.6462.02 ─ 20
OFF (0)
The frequencies only reach down to the start frequency of the
instrument sweep.
Options: R&S ZNA-K210
Manual operation: See "DC Extrapolation" on page 687
CALCulate:FMODel:EZD<Ph_pt>:DUT:MEASure
For a fixture modeling with the EZD tool, this command allows to measure "DUT + Test
Fixture" at the active ports (see CALCulate:FMODel:EZD<Ph_pt>:DUT[:STATe])
Suffix:
<Ph_pt>
.
This suffix is ignored.
Usage: Event
Options: R&S ZNA-K210
Manual operation: See "Measure" on page 678
CALCulate:FMODel:EZD<Ph_pt>:DUT:MEASure:FILename <String>
For a fixture modeling with the EZD tool, this command loads the "DUT + Test Fixture"
properties from a Touchstone file.
Suffix:
<Ph_pt>
.
This suffix is ignored.
Parameters:
<String> Path to the Touchstone file, either absolute or relative to the
selected working directory (CALCulate:FMODel:DIRectory).
Options: R&S ZNA-K210
Manual operation: See "Load File" on page 678
CALCulate:FMODel:EZD<Ph_pt>:DUT:MEASure:FILename:CLEar
Invalidates the file path previously set using CALCulate:FMODel:EZD<Ph_pt>:
DUT:MEASure:FILename.
Suffix:
<Ph_pt>
.
This suffix is ignored.
Usage: Event
Options: R&S ZNA-K210
Manual operation: See "Load File / 1x Open Preset / 1x Short Preset" on page 677
SCPI command reference