Model 8210/8250 Maintenance Manual Section 3. Systems Overview
Operator Display and Programming
Publication:1146945/001, Revised: 25 Sep 2018 3-15
61 Li-Ion Battery
- SOC
Threshold
5% 1 to 16 1 4 Charge interval notification. State of
Charge range is from 5 to 80%.
1 = 5%
2 = 10%
3 = 15%
4 = 20%
5 = 25%
6 = 30%
7 = 35%
8 = 40%
9 = 45%
10 = 50%
11= 55%
12 = 60%
13 = 65%
14= 70%
15 = 75%
16 = 80%
62 Li-Ion Battery
- Alarm
Interval
min. 1 to 99 1 30 Audible alarm sounds once every 10
seconds and the beacon flashes. Range is
1-99 minutes with the alarm active.
Alarm triggers are:
• low state of charge
• exceeded time for scheduled charge
• imminent shutdown
• travel request while attached to AC
power source
• entering sleep mode
• exiting sleep mode (waking up)
63 Li-Ion Battery
- Sleep Delay
Timer (Key
On)
0 to 48 1 2 Verifies min/max/default timing for this
parameter. Sleep delay starts when the
amperage is below 6 amps, resets when
amperage goes above 6 amps with key
ON. Range is 0 to 48 in 30 minute
increments.
0 = Sleep Delay disabled
2 = 1 hour
64 Li-Ion Battery
- Sleep Delay
Timer (Key
Off)
0 to 48 1 2 Verifies min/max/default timing for this
parameter. Sleep delay starts when the
key is OFF, disables when the key is ON.
0 causes immediate power OFF with key
ON. Range is 0 to 48 in 30 minute
increments. (for example 2 = 1 hour)
65 Li-Ion Battery
- Dormant
Mode
20 to 100 1 20 Set state of charge between 20 and 100.
Dormant mode error persists until state
of charge is higher than this parameter.
66 Li-Ion Battery
- Low SOC
Threshold
5 to 10% 1 10% Set the low state of charge warning
SOC%. This is the value where “b_Lo”
error code appears on the Operator
Display. Truck top speed is limited.
Parameter Name Unit Range Step Default Description