SERVICE PROGRAM MODE
A265/A267 4-24 SM
Mode No.
Class
1 and 2
Class
3
Function Settings
Adjusts the magnification in the main scan
direction for the engine.
1
Main Scan
Magnification
(Engine)
Use the
!
key to toggle between + and -
before entering the value. The specification
is
±
0.5%.
This SP value affects all print modes (copy,
printer, and image rotation). If the main scan
magnification is not correct for copying, also
use SP2-998-2. For image rotation, use
SP2-998-3.
See “Replacement and
Adjustment - Copy Adjustment” for details,
Section 6.8.
-0.5 ~ +0.5
0.1 %/step
0.0 %
Adjusts the magnification in the main scan
direction for copying.
2
Main Scan
Magnification
(Copy)
This SP affects only copying. It is added to
the value of 2-998-1.
-0.5 ~ +0.5
0.1 %/step
0.0 %
Adjusts the magnification in the main scan
direction for copying with image rotation
mode.
2-998*
3
Main Scan
Magnification
(Image Rotation)
This SP affects only image rotation mode. It
is added to the value of 2-998-1.
-0.5 ~ +0.5
0.1 %/step
0.0 %
Adjusts the magnification in the main scan
direction for scanning.
4-008* 1
Main Scan
Magnification
(Scanner)
Use the
!
key to toggle between + and -
before entering the value. The specification
is
±
1%. See “Replacement and Adjustment
- Copy Adjustment” for details
, Section 6.8.
–1.0 ~ +1.0
0.1 %/step
0.0%
Adjusts the leading edge registration for
scanning in platen mode.
4-010*
Leading Edge
Registration
(Scanner)
(–): The image moves in the direction of the
leading edge.
Use the
!
key to toggle between + and -
before entering the value. The specification
is 2
±
1.5 mm. See “Replacement and
Adjustment - Copy Adjustment” for details
,
Section 6.8.
–5.0 ~ +9.0
0.1 mm/step
0.0 mm
Adjusts the side-to-side registration for
scanning in platen mode, Section 6.8.
4-011*
Side-to-side
Registration
(Scanner)
(–): The image disappears at the left side.
(+): The image appears.
Use the
!
key to toggle between + and -
before entering the value. The specification
is 2
±
1.5 mm. See section 6.8
“Replacement and Adjustment - Copy
Adjustment” for details,
–10.0 ~ +6.0
0.1 mm/step
0.0 mm