SERVICE PROGRAM MODE
A265/A267 4-46 SM
Mode No.
Class
1 and 2
Class
3
Function Settings
This SP is effective only for the European
version.
Selects the display language group.
See “Display language” for details.
5-807*
Display Language
Group
The actual display language can be selected
using SP5-808.
0: Standard
1: Option 1
2: Option 2
Selects the display language.
See “Display language” for details, Section
4.2.15.
5-808*
Display Language
For the European version, the display
languages are divided into the language
groups of SP5-807.
0: English
1: French
2: Spanish
5-809*
mm/inch Selection Selects whether mm or inches are used in
the display.
Eur./Asia
model
0: mm
1: inch
American
model
0: inch
1: mm
Resets all level A service call conditions,
such as fusing errors.
After selecting “1”, press the “Photo” key
and the
)
key at the same time to reset the
SC codes.
If the reset was successful, the beeper will
sound 5 times. If it failed, the beeper will
sound only twice.
After performing this SP mode, turn the
machine’s main switch off and on.
5-810
SC Code Reset
See “Troubleshooting - Service Call
Conditions” for how to use this mode.
0: No
1: Yes
Use to input the machine serial number.
(This is normally done at the factory.)
5-811
Serial Number Input
This serial number will be printed on the
SMC report. See the “Serial Number Input”
section 4.2.16 for details.
Use this to input the telephone number of
the service representative (this is displayed
when a service call condition occurs).
1
Service Telephone
Number (Telephone)
Press the
!
key if you need to input a
pause (–). Press the
&
(Clear/Stop) key to
delete the telephone number.
Use this to input the fax number which will
be printed on the user counter report.
5-812*
2
Service Telephone
Number (Facsimile)
Press the
!
key if you need to input a
pause (–). Press the
&
(Clear/Stop) key to
delete the telephone number.
5-816*
CSS Function
This SP is for Japan only. Do not change
the value.
0: No
1: Yes