SERVICE PROGRAM MODE
SM 4-47 A265/A267
Service
Tables
Mode No.
Class
1 and 2
Class
3
Function Settings
1
CE Start/Finish Call
(CE Start Call)
5-817
2
CE Start/Finish Call
(CE Finish Call)
This SP is for Japan only. Do not change the
value.
0: No
1: Yes
5-821
CSS-PI Device
Code
This SP is for Japan only. Do not change the
value.
0: No
1: Yes
Uploads SP and UP mode data (except for
counters and the serial number) from the flash
memory on the BICU board to a flash memory
card.
5-824
NVRAM Data
Upload
This SP can be used when a flash memory card
is plugged into the machine. See the “NVRAM
Data Upload” section 4.2.11 for details.
0: No
1: Yes
Downloads SP mode data from a flash memory
card to the flash memory on the BICU board.
5-825
NVRAM Data
Download
This SP can be used when a flash memory card
is plugged into the machine. See the “NVRAM
Data Download” section 4.2.11 for details.
0: No
1: Yes
Uploads the system program from the flash
memory on the BICU board to a flash
memory card.
5-826
Program Upload
This SP can be used when a flash memory
card is plugged into the machine. See the
“Program Upload” section 4.2.10 for details.
0: No
1: Yes
Downloads the system program from a flash
memory card to the flash memory on the
BICU board.
5-827
Program Download
This SP can be used when a flash memory
card is plugged into the machine. See the
“Program Download” section 4.2.10 for
details.
0: No
1: Yes
Performs a printer free run.
5-901
Printer Free Run
After selecting “1”, press “OK” or the
(
key
twice to start this feature. Press the
&
(Clear/Stop) key to stop.
0: No
1: Yes
Prints a test pattern.
5-902
Test Pattern Print
See the “Test Pattern Printing” section for
how to print a test pattern.
Change to the copy mode display by
pressing the
'
(Interrupt) key, then print
out the test pattern.
5-903*
LCD Contrast
Adjustment
Adjusts the contrast of the LCD on the
operation panel.
0 ~ 7
1 /step
3
Adjusts the auto off mode timer (also used
for night mode if a fax or printer option is
installed).
5-904*
Auto Off Timer
Setting
If this value is changed, the user tool setting
is also changed.
1 ~ 240
1 min/step
60 min
5-905*
CSS 25 Hours Off
Detection
This SP is for Japan only. Do not change
the value.