BIT SWITCHES
A265/A267 4-20 SM
System Switch 02
No FUNCTION COMMENTS
0-3
Not used Do not change the settings.
4 File retention time
0: Depends on User
Parameter 24 [18(H)]
1: No limit
1: A file that had a communication error will not
be erased unless the communication is
successful.
5
Not used Do not change the settings.
6
7
Memory read/write by RDS
Bit 7 6 Setting
0 0 Always disabled
0 1 User selectable
1 0 User selectable
1 1 Always enabled
(0,0): All RDS systems are always locked out.
(0,1), (1,0): Normally, RDS systems are locked
out, but the user can temporarily switch RDS on
to allow RDS operations to take place. RDS will
automatically be locked out again after a certain
time, which is stored in System Switch 03. Note
that if an RDS operation takes place, RDS will not
switch off until this time limit has expired.
(1,1): At any time, an RDS system can access the
machine.
System Switch 03
No FUNCTION COMMENTS
0
to
7
Length of time that RDS is
temporarily switched on when
bits 6 and 7 of System Switch
02 are set to “User selectable”
00 - 99 hours (BCD).
This setting is only valid if bits 6 and 7 of System
Switch 02 are set to “User selectable”.
The default setting is 24 hours.
System Switch 04
No FUNCTION COMMENTS
0-2
Not used Do not change the settings.
3 Printing dedicated tx
parameters on Quick/Speed
Dial Lists
0: Disabled
1: Enabled
1: Each Quick/Speed dial number on the list is
printed with the dedicated tx parameters (8 bytes
each).
The last 10 bytes of data are the programmed
dedicated tx parameters; 32 bytes of data are
printed (the other 22 bytes have no use for
service technicians).
4
Not used Do not change the settings.