BIT SWITCHES
SM 4-45 A265/A267
Service
Tables
A895
Communication Switch 08
No FUNCTION COMMENTS
0
to
7
Not used Do not change the settings.
Communication Switch 09 - Not used (do not change the settings)
Communication Switch 0A
No FUNCTION COMMENTS
0
Point of resumption of
memory transmission upon
redialing
0: From the error page
1: From page 1
0: The transmission begins from the page where
transmission failed the previous time.
1: Transmission begins from the first page, using
normal memory transmission.
1-6
Not used Do not change the settings.
7 Emergency calls using 999
0: Enabled 1: Disabled
If this bit is at 1, the machine will not allow you to
dial 999 at the auto-dialer. This is a PTT
requirement in the UK and some other countries.
Communication Switch 0B
No FUNCTION COMMENTS
0 Use of Economy
Transmission during a
Transfer operation to end
receivers
0: Disabled 1: Enabled
These bits determine whether the machine uses
the Economy Transmission feature when it is
carrying out a Transfer operation as a Transfer
Station.
1
Use of Economy
Transmission during a
Transfer operation to the Next
Transfer Stations
0: Disabled 1: Enabled
2 Use of Label Insertion for the
End Receivers in a Transfer
operation
0: Disabled 1: Enabled
This bit determines whether the machine uses the
Label Insertion feature when it is carrying out a
Transfer operation as a Transfer Station.
3
Conditions required for
Transfer Result Report
transmission
0: Always transmitted
1: Only transmitted if there
was an error
0: When acting as a Transfer Station, the
machine will always send a Transfer Result
Report back to the Requesting Station after
completing the Transfer Request, even if there
were no problems.
1: The machine will only send back a Transfer
Result Report if there were errors during
communication, meaning one or more of the End
Receivers could not be contacted.