BIT SWITCHES
SM 4-49 A265/A267
Service
Tables
A895
Communication Switch 14
No FUNCTION COMMENTS
6
to
7
Available unit of resolution in
which fax messages are
received
Bit 7 Bit 6 Unit
0 0 mm
0 1 inch
1 0 mm and inch
(default)
1 1 Not used
For the best performance, do not change the
factory settings.
The setting determined by these bits is informed
to the transmitting terminal in the pre-message
protocol exchange (in the DIS/NSF frames).
Communication Switch 15 - Not used (do not change the settings)
Communication Switch 16
No FUNCTION COMMENTS
0
Not used Do not change the settings.
1
Optional G3 unit
0: Not installed
1: Installed
Change this bit to 1 when installing the optional
G3 unit.
2
Optional ISDN unit
0: Not installed
1: Installed
Change this bit to 1 when installing the optional
ISDN unit.
3-4
Not used Do not change the settings.
5
Use of the PSTN-2 line
0: Tx or rx
1: Rx only
Change this bit to 1 when the customer requires.
6 G4 Dual communication
0: Enabled
1: Disabled
1: The machine uses only one B channel for
communication. This enables a customer to
occupy another B channel for other purposes
such as internet communication.
7
Not used Do not change the setting.