ERROR CODES
SM 7-5 A265/A267
Trouble-
shooting
A895
Code Meaning Suggested Cause/Action
0-75
The called terminal fell
back to T.30 mode,
because it could not detect
a CM in response to
ANSam (ANSam timeout).
The terminal could not detect ANSam.
Check the line connection and condition.
Try receiving a call from another V.8/V.34 fax.
0-76 The calling terminal fell
back to T.30 mode,
because it could not detect
a JM in response to a CM
(CM timeout).
The called terminal could not detect a CM due
to noise, etc.
Check the line connection and condition.
Try making a call to another V.8/V.34 fax.
0-77 The called terminal fell
back to T.30 mode,
because it could not detect
a CJ in response to JM
(JM timeout).
The calling terminal could not detect a JM due
to noise, etc.
A network that has narrow bandwidth cannot
pass JM to the other end.
Check the line connection and condition.
Try receiving a call from another V.8/V.34 fax.
0-79 The called terminal
detected CI while waiting
for a V.21 signal.
Check for line noise or other line problems.
If this error occurs, the called terminal falls back
to T.30 mode.
0-80
The line was disconnected
due to a timeout in V.34
phase 2 – line probing.
0-81 The line was disconnected
due to a timeout in V.34
phase 3 – equalizer
training.
0-82
The line was disconnected
due to a timeout in the
V.34 phase 4 – control
channel start-up.
0-83
The line was disconnected
due to a timeout in the
V.34 control channel
restart sequence.
The guard timer expired while starting these
phases. Serious noise, narrow bandwidth, or
low signal level can cause these errors.
If these errors happen at the transmitting terminal:
Try making a call at a later time.
Try using V.17 or a slower modem using
dedicated tx parameters.
Try increasing the tx level.
Try adjusting the tx cable equalizer setting.
If these errors happen at the receiving terminal:
Try adjusting the rx cable equalizer setting.
Try increasing the tx level.
Try using V.17 or a slower modem if the same
error is frequent when receiving from multiple
senders.
0-84
The line was disconnected
due to abnormal signaling
in V.34 phase 4 – control
channel start-up.
The signal did not stop within 10 s.
Turn off the machine, then turn it back on.
If the same error is frequent, replace the FCU.
0-85 The line was disconnected
due to abnormal signaling
in V.34 control channel
restart.
The signal did not stop within 10 s.
Turn off the machine, then turn it back on.
If the same error is frequent, replace the FCU.
0-86 The line was disconnected
because the other terminal
requested a data rate
using MPh that was not
available in the currently
selected symbol rate.
The other terminal was incompatible.
Ask the other party to contact the
manufacturer.