INSTALLATION PROCEDURE
A265/A267 1-2 SM
3. Remove the NCU [A] from the NCU unit (4 screws). Connect the harness [B] to
the FCU (CN604).
4. Attach the G4 unit [C] to the machine (6 screws, 1 connector).
5. Connect the harness [B] to the interface board and attach bracket [D] (1 screw).
Then attach the NCU [A] (removed from the NCU unit in step 3) to the G4 unit
(4 screws). After that, connect the harness [E] to the NCU [A], then clamp
harness [E] as shown.
A895I353.WMF
A895I311.WMF
A895I392.WMF
[B]
[A]
[A]
[D]
[E]
[C]
[B]