Using SP Modes
D096 5-6 SM
5. Select "Execute." The messages "Execute?" followed by "Cancel" and "Execute"
shows.
6. Select "Execute."
7. When the program has ended normally, the message "Completed" shows. If the
program has ended abnormally, an error message shows.
8. Press the cancel key.
9. Turn the main switch off and on.
10. Download the NVRAM data from a flash memory card (
NVRAM Data
Upload/Download (SP 5824/5825))
- Without Flash Memory Card -
1. Print out all SMC data lists (
SMC Print (SP 5990)).
2. Select SP 5-801.
3. Press the OK key.
4. Select "Execute." The messages "Execute?" followed by "Cancel" and "Execute"
show.
5. Select "Execute."
6. When the program has ended normally, the message "Completed" is displayed. If the
program has ended abnormally, an error message shows.
7. Turn the main switch off and on.
8. Adjust the printer and scanner registration and magnification (
p.4-58 "Copy
Adjustments Printing/Scanning").
9. Refer to the SMC lists, and enter any values that differ from the factory settings.
Double-check the values for SP 4901.
10. Adjust the standard white level (SP 4428).
11. Initialize the TD sensor (SP 2214).
12. Check the copy quality and the paper path.