279User Manual 1173.9105.02 ─ 12
Parameters:
<State> 0 | 1 | OFF | ON
11.23 UNIT Subsystem
The UNIT subsystem contains the commands specifying which units are valid if no unit
is indicated in a command. These settings are valid for the entire instrument.
:UNIT:ANGLe <Angle>
Sets the default angle unit for remote control. Does not influence the manual control
parameter units and the display.
Parameters:
<Angle> DEGRee | RADian
*RST: RADian
Example:
UNIT:ANGL DEG
sets DEG as a default unit for all commands which determine
angle values.
:UNIT:POWer <Power>
Defines the default unit for power parameters. This setting affects the GUI, as well as
all remote control commands that determine power values.
Parameters:
<Power> V | DBUV | DBM
*RST: DBM
Example:
UNIT:POW V
sets V as a default unit for all commands which determine power
values.
11.24 List of R&S SGS Commands
:CALibration:ALL[:MEASure]?....................................................................................................................... 205
:CALibration:FREQuency:TEMPerature?...................................................................................................... 207
:CALibration:FREQuency[:MEASure]?.......................................................................................................... 206
:CALibration:IQModulator:FULL?...................................................................................................................206
:CALibration:IQModulator:LOCal?................................................................................................................. 206
:CALibration:IQModulator:TEMPerature?......................................................................................................207
:CALibration:LEVel:TEMPerature?................................................................................................................ 207
:CALibration:LEVel[:MEASure]?.................................................................................................................... 206
:CALibration:OEXTension.............................................................................................................................. 207
:CALibration:ROSCillator:DATA:MODE......................................................................................................... 207
:CALibration:ROSCillator[:DATA]................................................................................................................... 208
List of R&S SGS Commands