EasyManua.ls Logo

Rohde & Schwarz SGS100A - Table of Contents

Rohde & Schwarz SGS100A
324 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Signal Generator Settings
R&S
®
SGS100A
109User Manual 1173.9105.02 ─ 12
Source...........................................................................................................110
Frequency .................................................................................................... 110
Level Offset State,Level Offset......................................................................110
Filter.............................................................................................................. 110
Filter Length.................................................................................................. 111
Auto Once..................................................................................................... 111
Noise Content................................................................................................111
Timeout..........................................................................................................111
Default Aperture Time................................................................................... 111
Aperture Time................................................................................................112
S-Parameter .................................................................................................112
Enable Logging............................................................................................. 112
Sensor type and serial number
Indicates the type and the serial number of the selected R&S NRP power sensor, and
the channel the sensor is assigned to.
The displayed Level (Peak) / Level (Average) values correspond to the particular sen-
sor.
Remote command:
:SENSe<ch>[:POWer]:TYPE? on page 235
:SENSe<ch>[:POWer]:SNUMber? on page 233
Level (Peak) / Level (Average)
Indicates the measured peak or average level value.
You can also change the unit for the results display: Watt, dBm or dBμV.
Note: Peak level measurements are provided if the power sensor supports this feature.
Remote command:
:READ<ch>[:POWer]? on page 227
:SENSe<ch>:UNIT[:POWer] on page 228
Sensor Mapping
Accesses the NRP Sensor Mapping dialog.
Sensor Settings
One tab per sensor provides the corresponding setting parameters.
State ← Sensor Settings
Activates level measurement.
Remote command:
:INITiate<hw>[:POWer]:CONTinuous on page 227
To query the availability of a sensor at a given connector, use the command :
SENSe<ch>[:POWer]:STATus[:DEVice]? on page 234.
Zero ← Sensor Settings
Activates the auto zeroing.
For details, see "About zeroing" on page 106.
Level and Power-On Settings

Table of Contents

Related product manuals