Signal Generator Settings
R&S
®
SGS100A
109User Manual 1173.9105.02 ─ 12
└ Source...........................................................................................................110
└ Frequency .................................................................................................... 110
└ Level Offset State,Level Offset......................................................................110
└ Filter.............................................................................................................. 110
└ Filter Length.................................................................................................. 111
└ Auto Once..................................................................................................... 111
└ Noise Content................................................................................................111
└ Timeout..........................................................................................................111
└ Default Aperture Time................................................................................... 111
└ Aperture Time................................................................................................112
└ S-Parameter .................................................................................................112
└ Enable Logging............................................................................................. 112
Sensor type and serial number
Indicates the type and the serial number of the selected R&S NRP power sensor, and
the channel the sensor is assigned to.
The displayed Level (Peak) / Level (Average) values correspond to the particular sen-
sor.
Remote command:
:SENSe<ch>[:POWer]:TYPE? on page 235
:SENSe<ch>[:POWer]:SNUMber? on page 233
Level (Peak) / Level (Average)
Indicates the measured peak or average level value.
You can also change the unit for the results display: Watt, dBm or dBμV.
Note: Peak level measurements are provided if the power sensor supports this feature.
Remote command:
:READ<ch>[:POWer]? on page 227
:SENSe<ch>:UNIT[:POWer] on page 228
Sensor Mapping
Accesses the NRP Sensor Mapping dialog.
Sensor Settings
One tab per sensor provides the corresponding setting parameters.
State ← Sensor Settings
Activates level measurement.
Remote command:
:INITiate<hw>[:POWer]:CONTinuous on page 227
To query the availability of a sensor at a given connector, use the command :
SENSe<ch>[:POWer]:STATus[:DEVice]? on page 234.
Zero ← Sensor Settings
Activates the auto zeroing.
For details, see "About zeroing" on page 106.
Level and Power-On Settings