Chapter 3
Device Management
RUGGEDCOM RSG2488
User Guide
60 Viewing the Status of Ports
controller, it will stop generating a link signal. The controller will detect the link failure and failover to the backkup
port.
IMPORTANT!
If both link partners have the LFI feature, it must not be enabled on both sides of the link. If it is enabled
on both sides, the link will never be established, as each link partner will be waiting for the other to
transmit a link signal.
The switch can also be configured to flush the MAC address table for the controller port. Frames destined for the
controller will be flooded to Switch B where they will be forward to the controller (after the controller transmits its
first frame).
Section 3.7.2
Viewing the Status of Ports
To view the current status of each Ethernet port, navigate to Ethernet Ports > View Port Status. The Port Status
table appears.
Figure 22: Port Status Table
This table displays the following information:
Parameter Description
Port Synopsis: 1/1 to 8/2