Chapter 3
Device Management
RUGGEDCOM RSG2488
User Guide
72 Managing Switch IP Interfaces
Parameter Description
Specifies the IP address of this device. An IP address is a 32-bit number that is notated
by using four numbers from 0 through 255, separated by periods. Only a unicast IP
address is allowed, which ranges from 1.0.0.0 to 233.255.255.255.
Subnet Synopsis: ###.###.###.### where ### ranges from 0 to 255
Default: 255.0.0.0
Specifies the IP subnet mask of this device. An IP subnet mask is a 32-bit number that
is notated by using four numbers from 0 through 255, separated by periods. Typically,
subnet mask numbers use either 0 or 255 as values (e.g. 255.255.255.0) but other
numbers can appear.
4. Click Apply.
Section 3.8.2
Managing Switch IP Interfaces
The following sections describe how to set up and manage switch IP interfaces:
Section 3.8.2.1, “Viewing a List of Switch IP Interfaces”
Section 3.8.2.2, “Adding a Switch IP Interface”
Section 3.8.2.3, “Deleting a Switch IP Interface”
Section 3.8.2.1
Viewing a List of Switch IP Interfaces
To view a list of switch IP interfaces configured on the device, navigate to Administration > Configure IP
Interfaces > Configure Switch IP Interfaces. The Switch IP Interfaces table appears.
Figure 33: Switch IP Interfaces Table
If switch IP interfaces have not been configured, add IP interfaces as needed. For more information, refer to
Section 3.8.2.2, “Adding a Switch IP Interface”.
Section 3.8.2.2
Adding a Switch IP Interface
To add a switch IP interface, do the following:
1. Navigate to Administration > Configure IP Interfaces > Configure Switch IP Interfaces. The Switch IP
Interfaces table appears.