Chapter 3
Device Management
RUGGEDCOM RSG2488
User Guide
84 Adding an RMON Alarm
Section 3.11.2.2
Adding an RMON Alarm
To add an RMON alarm, do the following:
1. Navigate to Ethernet Stats > Configure RMON Alarms. The RMON Alarms table appears.
1
Figure 51: RMON Alarms Table
1. InsertRecord
2. Click InsertRecord. The RMON Alarms form appears.
8
12
13
7
6
5
4
3
2
1
10
9
11
14
Figure 52: RMON Alarms Form
1. Index Box 2. Variable Box 3. Rising Thr Box 4. Falling Thr Box 5. Value Box 6. Type Options 7. Interval Box 8. Startup
Alarm List 9. Rising Event Box 10. Falling Event Box 11. Owner Box 12. Apply Button 13. Delete Button 14. Reload Button
3. Configure the following parameter(s) as required:
Parameter Description
Index Synopsis: 1 to 65535
Default: 1
The index of this RMON Alarm record.
Variable Synopsis: SNMP Object Identifier - up to 39 characters