Total Station Manual
guarantee its capacity under other modes .Because consumption of power in
distance measurement mode is more than that in angle measurement mode ,the
instrument may end ranging sometimes due to insufficient capacity of battery
(when switching between modes).
Notice in charging:
Though overcharging protection is installed in the instrument, please plug off the
battery immediately after finishing charging.
Charging range from 0°~±45℃ . Abnormal responds of instrument occurs over
this range.
Rechargeable for300—500 times, it may shorten Service time of the battery
completely.
Charge the battery once a month no matter if it is used to prolong its longevity.
When measuring distance with prism mode, a reflecting prism must be set
at the target site. You can connect the prism to the base, and then connect the
base onto the tripod .you can also set the prism onto the centering rod. There
are single-prism group and three prism group available on the market, so you
can select them according to your requirements.
5. Loading or unloading the base
Put the three fixed feet in the corresponding bases, make the instrument in
a triangular base, clockwise lock the button by 180°to lock the base, and then
fix screw with a screwdriver to screw it out at a fixed lock knob.
● Unloading
If necessary, the triangle base can be removed from the instrument
(including the same base of reflection prism base connector) by loosening the
lock knob base fixed screw with a screwdriver, and anticlockwise locking button
about 180°, then separate the instrument from base.
6. Adjust telescope objective and aiming target
Aiming method (reference)
① Rotate the telescope and point it to the bright sky and focus reticule clearly (by
rotating eyepiece in own direction and focusing reticule slowly ).
② Aim at the target with the crosswire in optical sight , and keep an appropriate
distance when aiming ( about 200mm).
③ Use telescope focus screw to make target clear.