4. Functions
Bring the total station’s common functions and settings together, they can be
used in the process of measurement conveniently. In the function of Q-Survey which
in the Main menu or other interface of measurement in the program, you can press
[FNC] to enter the menu of Function
The menu of Function has 4 pages, you can press PAGE to view.
The specific introduction as follows:
You can open Function menu to select the function you want to use, you can
also define the function which on the Function menu to the key of [USER1] or
[USER2], then press the key of [USER1] or [USER2] to use these functions.
1. Level
When the compensator is on, Compensator can compensate to the tilt caused
by the instrument is not level. Manually level the instrument with the tribrach screws
to make the compensation value of compensator tend to 0, by doing these can make
the instrument tend to level. When the instrument is level, the laser plummet is in
the direction vertical, the place of laser points is the place of instrument station.