197
-
10. Technical parameters
Function
Unit
Configuration
SLT2
Telescope
Imaging
—
Erect
Magnification
×
30
Field of view
—
1
゜
20′
Min.target distance
m
1.5
Effective aperture
mm
40/50(EDM)
Angle
measurement
(Hz, V)
2C index error
(″)
1.4
Angle i index error
(″)
2.0
Angle measurement method
—
Absolute encoder
Minimum reading
(″)
1
Distance
measurement
(IR)
Range
Single prism
km
3
Triple prism
km
5
No- prism
1
m
400/600/800
Time
Repeated
s
2(first 3)
Tracking
s
0.8
Minimum display
mm
0.1
Accuracy
Prism
mm
±(2
+
2×10
-6
D)
No- prism
±(3+2×10
-6
D)
Tilt compensator
Compensation method
—
Biaxial type
Compensation range
(′)
±3
Communication Port
—
RS232C
U disk interface
—
Yes
Bluetooth
—
Yes
Temperature and pressure sensor
—
Yes
Display
Screen
—
Both sides(280*160, Black and white
screen)

Table of Contents