Total Station Manual
◆ Press [On] to open the compensator and press [Off] to close the compensator.
◆ Press [X Only] to open the compensator of X direction.
◆ Press [▲][▼] to adjust the laser plummet brightness.
◆ Press [OK] to close the laser plummet and exit.
The Offset is used to measure the points which are not intervisible, or
intervisibility but can not set up prism in the Station.
Offset contains Dist. Offset and two subprograms, the two subprograms are
Cylinder Offset and Angle Offset.
Using the external tools to measure the Offset values of the target point p2 and
measurement point p1 along the line of station point and measurement point, the
Offset values are Trav.OFS, LengthOFS and HeighOFS. Combining the information of
measuring point (p1) can calculate the distance of station point (p0) to target point
(p2), can also calculate the angel and coordinate.
When the measurement point is set on the left of target point or the right of
target point, you should make the angle that between line of measurement point
and target point and the line of measurement and station point about equals 90°.