Total Station Manual
point and cylinder is in the bisector of angle of station point with cylinder in Hz Left
and Hz Right. Turning the instrument to make the collimation axis in the bisector of
angle that station point with cylinder in Hz Left and Hz Right, thus can measure the
distance between cylinder and station.
○
1 In the program of Q-Survey,
press [FNC] to enter the menu
of Function, then pressing [F2]
to enter the program of Offset.
○
2 Press [F2] to enter the
subprogram of Cylinder Offset.
○
3 Aim at the left edge of
cylinder, press [F1] to make sure
the angel of Hz Left, turn the
instrument to aim at the right
edge of cylinder and press [F2]
to make sure the angle of Hz
Right.
○
4 Turn the instrument to make
△Hz=0, if use the prism,please
input the thickness of prism in
the edit text of PrismOFS, if
don’t use the prism, the default
value is 0 in the edit of
PrismOFS, then press [F3] to
measure the shortest distance
of the instrument to cylinder