Auto Lock
• On: The automatic lock mode is activated. If no button is actuated on the
receiver for approx. 10 minutes, the lock mode is automatically activat-
ed.
• Long-press the jog dial to temporarily deactivate the lock mode.
• Off: The automatic lock mode is deactivated.
RF Power
• Automatic: The transmission power is automatically adjusted.
• Level 1 ... 5: The transmission power can be manually reduced in 5 steps.
This function is required for operation in Multi-Room Mode.
Walk Test
• Starts the walk test. See „Performing a walk test (reception quality)”
Factory Reset
• Yes: All settings are reset to the factory defaults.
• No: The settings are retained.
System Info
• Displays the serial number and the current firmware version of the re-
ceiver.
The Network Settings menu
The Network Settings menu at menu level 1 allows you to adjust the fol-
lowing settings.
Mode
• Automatic: The IP address is automatically assigned using DHCP. If no
DHCP server is available, the IP address is assigned by the SL Rack Re-
ceiver DW itself.
• Fixed IP: The IP address has to be entered manually.
mDNS
• Disabled: Deactivates mDNS to reduce the data volume transferred
across the network. This option is recommended for larger systems.
• Enabled: Activates mDNS to allow for automatic device detection. This
option is recommended for smaller systems with up to 30 devices.
IP
• Input of the IP address in Fixed IP mode
Subnet
• Input of the subnet mask in Fixed IP mode