4 START-UP AND PARAMETER SETTINGS
4.1.2 Installing SOPAS ET
Install SOPAS ET on a laptop/PC.
Start SOPAS ET.
Following the installation instructions of SOPAS ET.
4.1.2.1 Password for SOPAS ET menus
Certain device functions are first accessible after a password has been entered.
4.1.3 Connection to the device via USB line
Recommended procedure:
1 Connect the USB line to the MCU control unit (see “MCU processor board connections”,
page 51) and the laptop/PC.
2 Switch the device on.
3 Start SOPAS ET.
4 Search settings”
5 “Device family oriented search”
6 Click the desired MCU.
7 Make the settings:
Ethernet communication (always clicked)
USB communication (always clicked)
Serial communication: Click
8 Do not specify IP addresses.
9 A list of COM ports is shown.
Specify the COM port of the DUSTHUNTER.
If you do not know the COM port: see “Finding the DUSTHUNTER COM port”, page 58
10 Assign a name for this search.
11 “Finish”
4.1.3.1 Finding the DUSTHUNTER COM port
If you do not know your COM port: You can find the COM port with the Windows Device
Manager (Administrator rights are not required).
1 Disconnect the DUSTHUNTER from your laptop/PC.
2 Input: devmgmt.msc
User level Access to
0Operator
Displays measured values and system states
No password required
1Authorized operator
Displays, inquiries as well as start-up or adjustment to customer-
specific demands and diagnosis of necessary parameters.
Preset password: sickoptic