NOTE
A
ddressing the host and guest:
b
Apply 0 V DC to pin 1 (H/G) on the host (see table 8, page 67).
b
Apply 24 V DC to pin 1 (H/G) on the guest (see table 8, page 67).
When switching on the safety laser scanner in an EFI system, the following message
appe
ars briefly on the 7-segment display:
•
at the host
•
at the guest
NOTE
In an E
FI system with an S3000 or S300, the S300 Mini must be configured as the
guest. It must not be configured as the host.
3.2.8.1 Interoperability of variants
The different variants of the S300 Mini can be operated as a host or a guest with other
v
ariants or other safety laser scanner product families in an EFI system. The following
table shows which devices can form a network.
Interoperability with safety laser scanners
Table 3: Interoperability with safety laser scanners
S3000 Standard
S3000 Advanced
S3000 Professional
S3000 Remote
S3000 Expert
S300 Standard
S300 Advanced
S300 Professional
S300 Expert
S300 Mini Standard
1)
S300 Mini Remote
S300 Mini Standard – – – – – – – – – – –
S300 Mini Remote
l l l
l
2)
l l l l l
–
l
2)
1)
This device does not have an EFI interface so it cannot be used in an EFI system.
2)
Only in conjunction with a Flexi Soft safety controller or sens:Control device.
l = E
FI system supported
– = EFI system not supported
Interoperability with safety laser scanners in compatibility mode
T
he S300 Mini cannot form an EFI system with an S3000 or S300 operating in compat‐
ibility mode (for details on the compatibility mode of the S3000 and S300 safety laser
scanners, see their operating instructions. Current operating instructions can be found
online at: www.sick.com).
3.2.8.2 S300 Mini Remote on a Flexi Soft safety controller
The Flexi Soft safety controller supports 2 EFI strings to which up to 2 safety laser scan‐
ner
s (S3000, S300, S300 Mini) each can be connected. Applications with up to 4
safety laser scanners can therefore be implemented (see figure 44, page 55).
3 P
RODUCT DESCRIPTION
22
O P E R A T I N G I N S T R U C T I O N S | S300 Mini 8014170/ZA23/2019-11-14 | SICK