3.2.8.3 Automated Configuration Recovery (ACR)
ACI is a Flexi Soft main module function. This function can be used to store the configu‐
r
ation of the devices connected via EFI. When the ACR function is active and a device is
exchanged, the existing configuration is automatically transmitted to the newly-con‐
nected scanner.
NOTE
To use the ACR function, the replacement device must be of the same type (same type
code).
Prerequisites for using the ACR function
F
lexi Soft main module FX3-CPU2 or higher
Flexi Soft Designer version V1.5.0 or higher
Configuration and Diagnostic Software (CDS) version V3.6.8 or higher
NOTE
T
he scanner configuration can only be changed when ACR is deactivated.
If a configuration is detected that has been created using the ACR function, a
warning is displayed in the CDS. In this case you need to deactivate the ACR func‐
tion on this EFI string in the Flexi Soft Designer so the configuration can be
changed.
This warning also appears when a device for which ACR was previously activated is
to be used in a new environment or is to be reconfigured.
WARNING
P
ersons and parts of the body to be protected may not be recognized in case of non-
observance.
When the ACR function is active, it automatically overwrites the scanner configuration
with the configuration stored in the Flexi Soft main module.
b
After setting up the ACR function or replacing a scanner, check the safety function
of the devices.
For more details on ACR, see the Flexi Soft Hardware (SICK part no. 8012477) and
F
lexi Soft Software (SICK part no. 8012479) operating instructions.
Further topics
"Commissioning", page 93
3.2.8.4 Interoperability with sens:Control devices
The S300 Mini Remote safety laser scanner can be connected to the following
sens
:Control devices and thereby integrated into the respective bus system.
The UE4140-22I0000 PROFIsafe gateway
The UE1140-22I0000 PROFIBUS gateway
The UE1840-22H0000 Ethernet gateway
The UE1940-22I0000 CANopen gateway
The UE4740-20H0000 PROFINET IO gateway
3.3 Example applications
Overview
T
he examples shown are only intended to help with planning. Additional protective mea‐
sures for the application may need to be considered.
3 P
RODUCT DESCRIPTION
24
O P E R A T I N G I N S T R U C T I O N S | S300 Mini 8014170/ZA23/2019-11-14 | SICK
Subject to change without notice

Table of Contents

Other manuals for SICK S300 Mini

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK S300 Mini and is the answer not in the manual?

SICK S300 Mini Specifications

General IconGeneral
BrandSICK
ModelS300 Mini
CategoryScanner
LanguageEnglish

Related product manuals