Mobile applications Stationary applications
30 mm (
hand detection with smaller pro‐
tective field size)
40 mm (hand detection with larger protec‐
tive field size)
50 mm (leg detection with smaller protec‐
tive field size)
70 mm (leg detection with larger protective
field size)
2)
30 mm (hand detection with smaller pro‐
tective field size)
40 mm (hand detection with larger protec‐
tive field size)
50 mm (leg detection with smaller protec‐
tive field size)
70 mm (leg detection with larger protective
field size)
150 mm
3)
(body detection)
Manipulation prevention
The safety laser scanner checks whether in any 90° segment all measured values correspond
t
o the maximum distance value that can be measured.
If t
his is the case, the device shuts down
after 2 hours and signals .
If t
his is the case, the device shuts down
after 5 seconds and signals .
7.5.1 Resolution
Maximum protective field ranges
T
he maximum protective field range
4)
depends on the configured resolution. The follow‐
ing table shows the respective maximum protective field range of the three variants at
the resolutions that can be set:
Table 12: Maximum protective field ranges at different resolutions
Maximum protective field range
Short Range variant
30 mm (hand detection) 1.00 m
40 mm (hand detection) 1.00 m
50 mm (leg detection) 1.00 m
70 mm (leg detection) 1.00 m
Medium Range variant
30 mm (hand detection) 1.25 m
40 mm (hand detection) 1.60 m
50 mm (leg detection) 2.00 m
70 mm (leg detection) 2.00 m
Long Range variant
30 mm (hand detection) 1.25 m
40 mm (hand detection) 1.60 m
50 mm (leg detection) 2.10 m
70 mm (leg detection) 3.00 m
150 mm (body detection) 3.00 m
Complementary information
NOTE
Y
ou can configure the warning field up to 8 m for all resolutions. The detection capabil‐
ity within the warning field depends on the radiance factor of the objects to be
detected.
2)
IIn mobile applic
ations a resolution of only 70 mm is required for leg detection, as a coarser resolution is adequate for the detection of a
human leg due to the movement of the vehicle.
3)
Configurable only for the Long Range variant with a 3 m scanning range.
4)
Radial distance to the safety laser scanner.
7 C
ONFIGURATION
72
O P E R A T I N G I N S T R U C T I O N S | S300 Mini 8014170/ZA23/2019-11-14 | SICK
Subject to change without notice

Table of Contents

Other manuals for SICK S300 Mini

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK S300 Mini and is the answer not in the manual?

SICK S300 Mini Specifications

General IconGeneral
BrandSICK
ModelS300 Mini
CategoryScanner
LanguageEnglish

Related product manuals