Figure 17: Prevent crawling beneath, standing behind, or climbing over
NOTICE
b
Mount t
he device in a dry location. Protect it from contamination and damage.
b
Avoid installing the device near strong electrical fields. These fields can be caused,
for example, by nearby welding cables, induction cables, or cell phones.
NOTE
b
Mount t
he device so that it is protected from moisture, dirt, and damage.
b
Mount the sensor so that the status indicators can be clearly seen.
b
Avoid exposing the device to excessive shock and vibration.
b
For systems that vibrate heavily, use shock absorbers to prevent the possibility of
fixing screws unintentionally coming loose.
b
Regularly check the tightness of the fixing screws.
b
Observe the maximum permissible tightening torque of 5.9 Nm for the M5 fixing
screws on the device.
Further topics
"Mount
ing", page 58
4.3.1 If several safety laser scanners are used
The device has been designed to minimize the probability of mutual interference with
o
ther safety laser scanners. To completely rule out unintended shutdowns, the safety
laser scanners must be mounted as shown in the following examples.
NOTE
T
o calculate the minimum distance for any particular case, refer to ISO 13855.
To adjust the safety laser scanners at different angles, use mounting kits 1 and 2.
PROJECT PLANNING 4
8014170/ZA23/2019-11-14 | SICK O P E R A T I N G I N S T R U C T I O N S | S300 Mini
31
Subject to change without notice

Table of Contents

Other manuals for SICK S300 Mini

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK S300 Mini and is the answer not in the manual?

SICK S300 Mini Specifications

General IconGeneral
BrandSICK
ModelS300 Mini
CategoryScanner
LanguageEnglish

Related product manuals