As inputs (you can select only one function per universal I/O connection):
St
andby
External device monitoring (EDM)
Reset the restart interlock
As outputs (you can select more than one function per universal I/O connection; these
are linked by the operator OR):
Device error
Contamination error
Contamination warning
Warning field 2
Reset required
NOTE
Other configurable functions depend on the configuration of the universal I/Os. For
example, you can only implement a restart interlock if you configure one of the univer‐
sal I/Os as an input for resetting the restart interlock.
You can configure the universal I/O connections in the U
niversal I/O area in the CDS.
Figure 58: Configuration example for the universal I/O connections of the S300 Mini Standard
Standby
If
, in mobile applications, vehicles are not moved for a time, the OSSDs can be switched
to the OFF state and the laser on the device can be switched off. In this way the power
consumption of the device is reduced.
The device remains in standby mode as long as the relevant input information is pend‐
ing.
CONFIGURATION 7
8014170/ZA23/2019-11-14 | SICK O P E R A T I N G I N S T R U C T I O N S | S300 Mini