Obstructions in the Sound Beam ......................................................................................... 235
Nozzle Mountings .................................................................................................................... 235
Set the MultiRanger to Ignore the Bad Echo .................................................................... 236
Wrong Reading ................................................................................................................................... 236
Types of Wrong Readings ...................................................................................................... 236
Liquid Splashing ........................................................................................................................ 236
Adjust the Echo Algorithm ..................................................................................................... 236
Transducer Ringing ............................................................................................................................ 237
Unit Repair and Excluded Liability ....................................................................................... 238
General Appendix D: Pump Control Reference ..................................................................... 239
Pump Control Options ....................................................................................................................... 239
Pump Groups ............................................................................................................................. 239
Pump by Rate [MR 200] ..........................................................................................................239
Pump Control Algorithms ................................................................................................................. 239
Fixed Duty Assist (P111 = 50) ................................................................................................. 240
Fixed Duty Backup (P111 = 51) [MR 200] ............................................................................ 240
Alternate Duty Assist (P111 = 52) ........................................................................................ 241
Alternate Duty Backup (P111 = 53) [MR 200] ..................................................................... 242
Service Ratio Duty Assist (P111 = 54) [MR 200] ................................................................ 242
Service Ratio Duty Backup (P111 = 55) [MR 200] ............................................................. 243
First In First Out (FIFO) (P111 = 56) [MR 200] ...................................................................... 243
Pump by Rate (P121) [MR 200] .............................................................................................. 243
Other Pump Controls [MR 200] ....................................................................................................... 243
General Appendix E: Updating Software .................................................................................. 245
Updating Software ............................................................................................................................. 245
General Appendix F: Upgrading ..................................................................................................... 246
Mounting a MultiRanger 100/200 ......................................................................................... 246
Connecting the Transducer ................................................................................................... 246
Coaxial Transducer Extention..................................................................................... 246
Connecting a transducer with RG62 coaxial extension cable............................. 247
MultiRanger Plus to MultiRanger 100/200 Parameters .................................................. 248
General Appendix G: Conduit Entry for Class 1, Div 2 Applications ........................... 249
Appendix H: Software Revision History .................................................................................... 251
MultiRanger 100 ................................................................................................................................. 251
MultiRanger 200 ................................................................................................................................. 254
Programming Charts ............................................................................................................................. 257

Table of Contents

Other manuals for Siemens MAG 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens MAG 5000 and is the answer not in the manual?

Siemens MAG 5000 Specifications

General IconGeneral
TypeElectromagnetic Flowmeter
Protection ClassIP67
MaterialStainless Steel, Carbon Steel
Power Supply24 V DC, 100-240 V AC
Accuracy±0.2% of flow rate
CommunicationHART, PROFIBUS, Modbus
Enclosure RatingIP67
Ambient Temperature Range-20°C to +60°C
SizesDN 2 to DN 3000
Lining MaterialsPTFE, Hard Rubber
Electrode MaterialsStainless Steel, Hastelloy, Tantalum
Process Temperature-40 to +180 °C (-40 to +356 °F) depending on liner
Process PressureUp to 40 bar (580 psi)
ApprovalsATEX, FM, CSA, IECEx
Flow Velocity Range0 to 12 m/s
Output Signals4-20 mA, Pulse, Frequency