7ML19981FB05 MultiRanger 100/200 – INSTRUCTION MANUAL Page 155
mmmmm
Parameters
P301 Temperature, Transducer Minimum
View the lowest temperature encountered, as measured by the temperature sensor in
the transducer (if applicable).
Press CLEAR keys to reset the log after an open circuit on the transducer wiring.
P302 Temperature, Sensor Maximum
View the highest temperature encountered, as measured by the TS-3 Temperature
Sensor (if applicable).
Press CLEAR keys to reset the log after a short circuit on the transducer wiring.
P303 Temperature, Sensor Minimum
Shows the lowest temperature encountered, as measured by the TS-3 Temperature
Sensor (if applicable).
Press CLEAR keys to reset the log after an open circuit on the transducer wiring.
Primary Index Transducer
Values
Range: - 50 to 150°C (view only)
Preset: 150°C
Related • P300 Temperature, Transducer Max
Primary Index Global
Values
Range: - 50 to 150°C (view only)
Preset: - 50°C
Related • P303 Temperature, Sensor Min
Primary Index Global
Values
Range: - 50 to 150°C (view only)
Preset: 150°C
Related • P302 Temperature, Sensor Max