Parameter
Description Data Read/write
P053*
Parameter Access
53
Function parameter for releasing interfaces for
parameterization.
0 Hex = None
1 Hex = Cbx communication board
2 Hex = PMU operator control panel
4 Hex = Serial interface (SCom/SCom1), also OP1S and
PC
8 Hex = SCB serial input/output modules
10 Hex = Txxx technology board
20 Hex = Serial interface 2 (SCom2)
40 Hex = Second CB board
Each interface has a code number. When the number or
the sum of different numbers assigned to the interfaces
is/are entered, the interface(s) is/are released for use as a
parameterizing interface.
Example:
The factory-setting value 6 is the sum of 2 and 4. This
means that parameterization is allowed via the PMU and
serial interface 1 and thus for the OP1S as well.
The parameter can always be written from any interface.
This also applies if this interface has not been released
for parameterization purposes.
During factory setting via CBx, SCB, TXXX, SCom2 or a
second CB board, this parameter is not reset.
Init: 7
Min: 0
Max: 127
Unit: -
Indices: -
Type: V2
Menus:
All menus
Changeable in:
All states
r054
Requester
54
This visualization parameter returns the origin of the read
request. It can therefore be scanned to find out which
interface is being used.
The values correspond to those of P53.
Dec.Plc.: 0
Unit: -
Indices: -
Type: L2
Menus:
- User parameters-
Parameter menu
+ General parameters
- Fixed settings
- Quick parameterization
- Board configuration
- Drive setting
- Download
- Upread/free access
- Power section definition
7
Siemens AG 6SE7087-6QX70 (Edition AL)
SIMOVERT MASTERDRIVES Compendium Motion Control