Parameter
Description Data Read/write
P139*
ConfSetpEnc
139
Function parameter for configuration of the setpoint
encoder on an SBP. The setpoint encoder can either
process one digital setpoint from two independent
rectangular-shaped frequency signals or, alternatively,
form one setpoint from an external pulse encoder signal
and a rectangular-shaped frequency signal.
xxx0 = channel 1 / encoder input HTL unipolar
xxx1 = channel 1 / encoder input TTL unipolar
xxx2 = channel 1 / encoder input HTL differential input
xxx3 = channel 1 / encoder input TTL/RS422 differential
input
xx0x = channel 2 HTL unipolar
xx1x = channel 2 TTL unipolar
xx2x = channel 2 HTL differential input
xx3x = channel 2 TTL/RS422 differential input
x0xx = encoder with 5 V voltage supply
x1xx = encoder with 15 V voltage supply
0xxx = setpoint encoder deactivated
1xxx = Frequency counter mode (frequency evaluation )
2xxx = Encoder signal evaluation mode
Init: 0
Unit: -
Indices: -
Type: L2
Menus:
- Parameter menu
+ Motor/encoder
+ Encoder data
- Board configuration
- Drive setting
- Upread/free access
Changeable in:
- Board configuration
P140*
SetpEnc Pulse#
140
Function parameter for the pulse number of the setpoint
encoder.
The parameter has to be set to the number of pulses of
the setpoint encoder connected to an SBP board.
If the first frequency channel of the setpoint encoder is in
the "encoder signal evaluation" mode (P139=2xxx), the
parameter value is used for normalizing the setpoint
generation (together with the motor ref. frequency).
Index 1: Channel 1
Index 2: Channel 2
index1: 1024
Min: 60
Max: 20000
Unit: -
Indices: 2
Type: O2
Menus:
- Parameter menu
+ Motor/encoder
+ Encoder data
- Drive setting
- Upread/free access
Changeable in:
- Drive setting
- Ready to switch on
P141*
SetpEncFreq
141
Function parameter for the reference frequency of the
setpoint encoder.
The parameter value determines which input frequency
results in an output of 100% on the setpoint encoder.
If the setpoint encoder is in the "frequency counter" mode
(P139=1xxx), the parameter values are used to normalize
the output values.
Index 1: Channel 1
Index 2: Channel 2
index1:
10000
Min: 500
Max:
1000000
Unit: Hz
Indices: 2
Type: O4
Menus:
- Parameter menu
+ Motor/encoder
+ Encoder data
- Drive setting
- Upread/free access
Changeable in:
- Drive setting
- Ready to switch on
19