Parameter
Description Data Read/write
P154*
FineResExtEnc
154
Function parameter for determining the fine resolution of
the external encoder.
The number of bits which are to contain the fine-resolution
information are input. The position actual-value is
expanded from the right by this information.
For this, the incoming rough position is pushed to the left
by the number of bits, and the fine-resolution bits are
assumed according to the position actual-value.
If an encoder or multiturn encoder with incremental tracks
(e.g. EQN1325) is used as an external encoder in
conjunction with an SMB2 as an evaluation board, fine
resolution is available. If another encoder or evaluation
board is used, the value zero is generally assumed as the
fine-resolution portion of the position.
Init: 0
Min: 0
Max: 30
Unit: -
Indices: -
Type: O2
Menus:
- Parameter menu
- Drive setting
- Upread/free access
Changeable in:
- Drive setting
- Ready to switch on
P155*
S.PosSetVMEncod
155
BICO parameter for selecting the connector from which
the position setting value is to be read in.
index1: 0
Unit: -
Indices: 2
Type: L2 ,K
,K
Menus:
- Parameter menu
+ Control/gating unit
+ Position control
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
P156*
S.SetPosMEncod
156
BICO parameter for selecting the binector from which the
command for setting the actual position is to be read in.
index1: 0
Unit: -
Indices: 2
Type: L2 ,B
Menus:
- Parameter menu
+ Control/gating unit
+ Position control
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
P157*
S.PosCorrVMEnc
157
BICO parameter for selecting the connector from which
the corrected position value is to be read in.
In function diagram 330.5
index1: 0
Unit: -
Indices: 2
Type: L2 ,K
,K
Menus:
- Parameter menu
+ Control/gating unit
+ Position control
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
P158*
S.CorrPosMEnc
158
BICO parameter for selecting the binectors from which the
commands for correcting the actual position are to be
read in.
Index 1: Addition of the corrected value
Index 2: Subtraction of the corrected value
index1: 0
Unit: -
Indices: 4
Type: L2 ,B
Menus:
- Parameter menu
+ Control/gating unit
+ Position control
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
P159*
S.RefSetVMEnc
159
BICO parameter for selecting the connector from which
the actual position is to be read in during the Reference-
Point Detection operating mode.
index1: 0
Unit: -
Indices: 2
Type: L2 ,K
,K
Menus:
- Parameter menu
+ Control/gating unit
+ Position control
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
27