Parameter
Description Data Read/write
P294*
Select Flux Reg
294
Function parameter for selecting the flux specification
when an induction motor is used.
0 = Controlled (closed-loop), flux controller active
1 = Controlled (open-loop), flux controller not active
2 = Controlled (closed-loop), flux controller active, flux
build-up with linear characteristic (smooth magnetization)
when drive is energized. The time characteristic is
determined by the contents of parameter P602 (Excitation
Time).
The smooth magnetization function is only available with
P296=3 (ASM field weakening).
Init: 0
Min: 0
Max: 2
Unit: -
Indices: -
Type: O2
Menus:
- Parameter menu
+ Control/gating unit
+ Current control
- Drive setting
- Upread/free access
Changeable in:
- Drive setting
P295
Mod Intervention
295
Connector input for manipulation of the model that is
based on the closed-loop control of the asynchronous
motor.
Index 1: Manipulation of the main inductance
Index 2: Manipulation of the rotor resistance
This intervention option should only be used by experts. It
is possible by intervening in particular in the use of
characteristic blocks to achieve an even greater torque
accuracy in the area of the current model (open-loop
operation).
These inputs are only effective if P296 is set to the value
3 (specialized closed-loop control for asynchronous
motors).
index1: 1
Unit: -
Indices: 2
Type: L2 ,K
Menus:
- Parameter menu
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
P296*
Dynamic I-Reg
296
Function parameter for selecting the dynamics of the
current controller. The number of sampling steps is
prescribed after which a setpoint step-change is to be fully
corrected.
0 = 2 sampling steps, highest dynamic response
1 = 3 sampling steps, medium dynamic response
2 = 4 sampling steps, lowest dynamic response
In function diagram: 389.6, 390.6
Init: 1
Min: 0
Max: 3
Unit: -
Indices: -
Type: O2
Menus:
- Parameter menu
+ Control/gating unit
+ Current control
- Drive setting
- Upread/free access
Changeable in:
- Drive setting
P297
Flux Reg. Gain
297
Function parameter for setting the flux controller gain.
Only effective for induction motors.
For future use. Not currently implemented!
Init: 0,00
Min: 0,00
Max: 50,00
Unit: -
Indices: -
Type: O2
Menus:
- Parameter menu
+ Control/gating unit
+ Current control
- Drive setting
- Upread/free access
Changeable in:
- Drive setting
P299*
FieldWeakDir
299
Service parameter, only for Siemens service personnel.
This parameter is for special applications ONLY and must
not be changed for standard operation.
Motor speed at which field weakening is applied for
synchronous machines.
In function diagram: 389.2
Init: 0
Min: 0
Max: 12000
Unit: 1/min
Indices: -
Type: O2
Menus:
- Parameter menu
+ Motor/encoder
+ Motor data
- Drive setting
- Upread/free access
Changeable in:
- Drive setting
P300*
SelectFieldWeak
300
Service parameter, only for Siemens service personnel.
DANGER: This parameter is for special applications
ONLY and must not be changed for standard operation.
Additional protective measures (overvoltage protection)
are required for operating synchronous machines during
field weakening.
Selection of field weakening for synchronous machines
In function diagram: 389.4
Init: 0
Min: 0
Max: 1
Unit: -
Indices: -
Type: O2
Menus:
- Parameter menu
+ Control/gating unit
+ Current control
- Drive setting
- Upread/free access
Changeable in:
- Drive setting
47
Siemens AG 6SE7087-6QX70 (Edition AL)
SIMOVERT MASTERDRIVES Compendium Motion Control