Parameter
Description Data Read/write
P301
Smooth Psi(act)
301
Function parameter for setting the smoothing time
constant for the rotor flux actual value in the EMF model.
Precondition:
P296=3 (ASM field weakening)
If the parameter is set to 0 an automatic adjustment of the
smoothing value takes place.
In function diagram 390a.3
Init: 0,0
Min: 0,0
Max: 2000,0
Unit: ms
Indices: -
Type: O2
Menus:
- Parameter menu
+ Control/gating unit
+ Speed control
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
P307
SrcEn HC
307
BICO parameter for selecting the binector from which the
command to enable the harmonic compensation function
is given.
index1: 0
Unit: -
Indices: 2
Type: L2 ,B
Menus:
- Parameter menu
+ Control/gating unit
+ Speed control
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
P308*
SrcAngleHC
308
Parameter contains the connector for the input signal of
harmonic compensation. Usually this parameter is
interconnected with the mechanical (KK0090) or electrical
KK0186) angle.
If the parameter is connected to the fixed connector
K0000, harmonic compensation is deactivated.
index1: 0
Unit: -
Indices: 2
Type: L2 ,K
,K
Menus:
- Parameter menu
+ Control/gating unit
+ Speed control
- Drive setting
- Upread/free access
Changeable in:
- Drive setting
- Ready to switch on
- Operation enabled
P309
HC Harmonic
309
Function parameter for entering the harmonic in the motor
torque to be compensated for.
With P309=0 compensation is deenergized.
index1: 1
Min: 1
Max: 12
Unit: -
Indices: 2
Type: O2
Menus:
- Parameter menu
+ Control/gating unit
+ Speed control
- Drive setting
- Upread/free access
Changeable in:
- Drive setting
- Ready to switch on
- Operation enabled
P310
HC Gamma
310
Function description for defining the phase position
between the basic shaft of the EMF(sine) at 0 degrees
and the torque compensation signal (sine) at 0 degrees
with a positive phase sequence.
index1: 0,00
Min: -180,00
Max: 180,00
Unit: ° (alt)
Indices: 2
Type: I2
Menus:
- Parameter menu
+ Control/gating unit
+ Current control
+ Free blocks
- Drive setting
- Upread/free access
Changeable in:
- Drive setting
- Ready to switch on
- Operation enabled
P311
HC Imax
311
Function description for defining the maximumm current
of amplitude adaptation of the harmonic compensation
signal, i.e. the quadratic characteristic stored in parameter
P312 is valid up to this current value.
Init: 0,0
Min: 0,0
Max: 2000,0
Unit: A
Indices: -
Type: O2
Menus:
- Parameter menu
+ Control/gating unit
+ Current control
- Drive setting
- Upread/free access
Changeable in:
- Drive setting
- Ready to switch on
- Operation enabled
48
Siemens AG 6SE7087-6QX70 (Edition AL)
SIMOVERT MASTERDRIVES Compendium Motion Control