08.2012 Parameterizing Steps
Siemens AG 6SE7087-6QX70 (Version AN)
SIMOVERT MASTERDRIVES Compendium Motion Control 6-13
The visualization parameter r826.x is used for displaying the board
codes. These codes enable the type of installed electronic boards to be
determined.
Parameter Index Position
r826 1 Basic board
r826 2 Slot A
r826 3 Slot B
r826 4 Slot C
r826 5 Slot D
r826 6 Slot E
r826 7 Slot F
r826 8 Slot G
If a technology board (T100, T300, T400) or an SCB1 or SCB2 is
inserted in mounting positions 3 or 2, their board code can be found in
the following indices:
Parameter Index Position
r826 5 Mounting position 2
r826 7 Mounting position 3
Parameter value Significance
90 to 109 Mainboards or Control Unit
110 to 119 Sensor Board (SBx)
120 to 129 Serial Communication Board (Scx)
130 to 139 Technology Board
140 to 149 Communication Board (Cbx)
150 to 169 Special boards (Ebx, SLB)
Board codes
General board
codes