Parameterizing Steps 08.2012
6SE7087-6QX70 (Version AN) Siemens AG
6-26 Compendium Motion Control SIMOVERT MASTERDRIVES
The OP1S operator control panel is capable of upreading parameter
(Upread or Upload) sets from the units and storing them. These
parameter sets can then be transferred to other units by download.
Downloading with the OP1S is thus the preferred method of
parameterizing replacement units in a service case.
During downloading with the OP1S, it is assumed that the units are in
the as-delivered state. The parameters for the power section definition
are thus not transferred. If a PIN has been entered to release optional
technology functions, this is also not overwritten during downloading.
(Refer to Section "Detailed parameterization, power section definition")
Parameter number Parameter name
P060 Menu selection
P070 Order No. 6SE70..
P072 Rtd Drive Amps(n)
P073 Rtd Drive Power(n)
P700 IF bus address
P701 IF baudrate
P702 IF no. of PKW
P703 IF no. of PZD
U977 PIN
Table 6-5 Parameters you cannot overwrite during download
Downloading with
the OP1S