EasyManuals Logo

Siemens simovert masterdrives Compendium

Siemens simovert masterdrives
1547 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #303 background imageLoading...
Page #303 background image
Communication / USS 02.2004
6SE7087-6QX70 (Version AD) Siemens AG
8.1-16 Compendium Motion Control SIMOVERT MASTERDRIVES
No. Meaning
0 Inadmissible legal parameter number (PNU); if PNU is not available
1
Parameter value cannot be changed; if the parameter is a visualization
parameter
2 Lower or upper limit exceeded
3 Erroneous sub-index
4 No array
5 Incorrect type of data
6 Setting not permitted (can only be reset)
7 Descriptive element cannot be changed; not possible
11 No operator control rights
12
Key word missing;
Drive converter parameter: ‘Access Key’ and/or ‘Parameter Special
Access’ not correctly set
15 No text array available
17
Task cannot be executed due to operating status; drive converter
status does not permit the set task at the moment
101
Parameter number deactivated at the moment; Parameter has no
function in the present state of the drive converter (e.g. type of closed-
loop control)
102
Channel width too small; only for short channels
The parameterized length of the PKW area is too large due to internal
limitations of the drive converter. This error message can occur with
the USS protocol on the T100 technology board only if access is made
to parameters of the basic unit from this interface.
103
Number of PKWs incorrect; only for G-SCom 1/2 and SCB interface
(USS);
The error number is transferred in the following two cases:
if the task concerns all the indices of an indexed parameter (task
index equal to 255) or the whole parameter description is
requested and a variable telegram length has not been
parameterized.
if the parameterized number of PKWs (process-data items) in the
telegram is too small for the set task (e.g. alteration from the
double word and the number of PKWs is 3 (words).
104
Parameter value not permissible;
This error number is transferred if the parameter value which is to be
transferred does not have an assigned function in the drive converter
or cannot be accepted at the instant of the change for internal reasons
(although it lies within the limits).
105
The parameter has been indexed
e.g. task ‘PWE change word’ for indexed parameter
106 Task not implemented
Table 8.1-7 Error numbers for the reply ID "Task cannot be executed"
Error numbers for
reply "Task cannot
be executed"

Table of Contents

Other manuals for Siemens simovert masterdrives

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens simovert masterdrives and is the answer not in the manual?

Siemens simovert masterdrives Specifications

General IconGeneral
BrandSiemens
Modelsimovert masterdrives
CategoryDC Drives
LanguageEnglish

Related product manuals