Error
number
Meaning Use Additional
info
0x00
Non-permissible parameter
number
Access to parameter that does not exist 0
0x01
Parameter value cannot be
changed
Change access to a parameter value
that cannot be changed
Subindex
0x02
Lower and upper value limit
exceeded
Change access with value outside the
value limits
Subindex
0x03 Incorrect subindex Access to subindex that does not exist Subindex
0x04 No array
Access with subindex to non-indexed
parameter
0
0x05 Wrong data type
Change access with value that does not
correspond with the data type of the
parameter
0
0x06
No setting permitted (can only
be reset)
Change access with value not equal to
0, where this is not permitted
Subindex
0x07
Description element cannot be
changed
Change access to description element
that cannot be changed
Subindex
0x08 Reserved
(PROFIdrive Profile V2: PPO write
request not available in Information
Report )
-
0x09 Description data not available
Access to description that does not exist
(parameter value available)
0
0x0A Reserved
(PROFIdrive Profile V2: Access group
incorrect)
-
0x0B No parameter change rights
Change access where there are no
parameter change rights
0
0x0C Reserved
(PROFIdrive Profile V2: Password
wrong)
-
0x0D Reserved
(PROFIdrive Profile V2: Text in cyclical
traffic cannot be read)
-
0x0E Reserved
(PROFIdrive Profile V2: Text in cyclical
traffic cannot be read)
-
0x0F No text array available
Access to text array that does not exist
(parameter value available)
0
0x10 Reserved (PROFIdrive Profile V2: No PPO Write) -
0x11
Task cannot be performed due
to operating state
Access is not possible due to temporary
reasons which have not been specified
in more detail
0
0x12 Reserved
(PROFIdrive Profile V2: Miscellaneous
error)
-
0x13 Reserved
(PROFIdrive Profile V2: Data cannot be
read in cyclical traffic)
-
0x14 Non-permissible value
Change access with value that lies
within the value limits but is not
acceptable for other permanent reasons
(parameter with defined individual
values)
Subindex