08.2012 Definitions and Warnings
Siemens AG 6SE7087-6QX70 (Version AN)
SIMOVERT MASTERDRIVES Compendium Motion Control 3
Residual risks of Power Drive Systems (PDS)
The components for the controller and drive of a Power Drive System (PDS) are
authorized for industrial and commercial use in industrial networks. Their use in
public networks requires a different planning and/or additional measures.
It is only permissible to operate these components in enclosed housings or in
superordinate control cabinets and when all protective devices and protective
covers are used.
These components may only be handled by qualified and trained specialist
persons who are familiar with and observe all the safety instructions on the
components and in the relevant technical user documentation.
The machine manufacturer must take into account the following residual risks resulting from the
components for the controller and drive of a Power Drive System (PDS) when evaluating the
risk of his machine in accordance with the EC machinery guideline.
1. Undesired movements of driven machine components during commissioning, operation,
maintenance and repair, e.g. as a result of
HW and/or SW errors in the sensors, controller, actuators and connection system
Reaction times of the controller and the drive
Operation and/or ambient conditions not compliant with the specification
Errors in parameterization, programming, wiring and installation
Use of radio units/mobile phones in the direct vicinity of the controller
External influences/damage.
2. Extraordinary temperatures and emissions of light, noises, particles and gases, e.g. as a
result of
Component failure
Software errors
Operation and/or ambient conditions not compliant with the specification
External influences/damage.
3. Dangerous contact voltages, e.g. as a result of
Component failure
Influence upon electrostatic charging
Induction of voltages in the case of moving motors
Operation and/or ambient conditions not compliant with the specification
Condensation/conductive contamination
External influences/damage.
4. Operational electrical, magnetic and electromagnetic fields that may pose a risk to people
with a pacemaker, implants or metallic items if they are too close.
5. Release of pollutants and emissions if components are not operated or disposed of properly.
For additional information on the residual risks emanating from the components of the PDS,
please refer to the relevant chapters of the technical user documentation.