4.10 Safety Integrated commissioning
Commissioning with Startdrive
Commissioning Manual, 11/2017, 6SL3097-4AA10-0BP1
259
Differences between Safe Speed Monitor with and without encoder
For Safe Speed Monitor without encoder, after pulse suppression the drive is unable to
determine the current velocity. Two responses can be selected for this operating state
with the "SSM active feedback for pulse inhibit" drop-down list:
"Becomes active": The status signal (SSM feedback signal) shows "0" (factory
setting).
"Becomes inactive": The status signal (SSM feedback signal) is frozen. "Safe Torque
Off" (STO) is selected internally.
Figure 4-108 SSM without encoder