Parame‐
ter
Signal Available control mode
F
ast PTI S T
r29404.1 Current control mode (CM_STA)
•
1: the second mode in compound control modes.
•
0: the rst mode in compound control modes or the ve basic mode.
- ✓ ✓
r46.8 Safety enable missing (STO_EP)
• 1: the enable signal is missing, indicating that S
TO is active.
• 0: the enable signal is available, indicating that STO is inactive.
Note: STO_EP is a status signal for STO terminals, not a safe DO for the Safety
Integrated function.
✓ ✓ ✓
The following signals are assigned to the digital outputs by default.
Table 9-5 Default signals of digital outputs
Digital
output
Par
ameter Default signal
S200 PTI S200 Basic PTI
DO0 c0730 TLR -
DO1 c0731 SPDR -
DO2 c0732 RDY RDY
DO3 c0733 FAULT FAULT
DO4 c0734 INP INP
DO5 c0735 - -
More information
For more information about wiring digit
al outputs, see Section "Connecting the inputs and
outputs (Page147)".
Parameters
The following list includes the parameters of the "Digital outputs" function.
Number Name Unit
r0046.0...30 Missing enable signals
c0730 Signal for terminal DO 0
c0731 Signal for terminal DO 1
c0732 Signal for terminal DO 2
c0733 CU signal for terminal DO 3
c0734 CU signal for terminal DO 4
c0735 CU signal for terminal DO 5
p0748.2...5 Digitalausgänge invertieren
p0748.0...5 Digitalausgänge invertieren
r0899.0...13 Status word sequence control
r1407.0...28 Status word speed controller
r2139.0...15 Status word faults/alarms 1
r2199.0...11 Status word monitoring 3
Functions
9.3Inputs/outputs
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA 233