The maximum speed p1082 is used as a reference value for calculating the ramps from
the ramp-up and ram
p-down time. For a quick stop (OFF3), a special adjustable ramp is
available via the ramp-down time p1135 (for example, for quick, controlled stopping after an
EMERGENCY OFF button has been pressed).
The following versions are available:
• Basic ramp-function generator (p1115=0)
• Extended ramp-function generator (p1115=1)
Basic ramp-function generator
The basic ramp-function generator is characterized by the following features:
• Ramp-up time T
up
(p1120)
• Ramp-down time T
dn
(p1121)
You can see the properties of the ramp-function generator from the diagram below:
7
XS
7
GQ
7
GQ
S
S
S
S
W
W
[
\
7
XS
Figure9-7 Basic ramp-function generator
Extended ramp-function generator
The extended ramp-function g
enerator is characterized by the following features:
• Ramp-up time T
up
(p1120)
• Ramp-down time T
dn
(p1121)
• Initial rounding IR (p1130)
Functions
9.6Speed control (S) (for S200 PTI only)
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2