Cause: The memory card has a defective 󹪝le.
Alarm value (r2124, interpret decimal):
xyz dec: x = pr
oblem, y = 󹪝le name
x = 1: 󹪝le checksum is incorrect.
x = 2: error when parsing the 󹪝le.
y = 1: 󹪝le MOTARM.ACX
y = 2: 󹪝le MOTARMLD.ACX
y = 3: 󹪝le MOTSRM.ACX
y = 4: 󹪝le MOTSLM.ACX
y = 5: 󹪝le MOTRESM.ACX
y = 6: 󹪝le BEARING.ACX
y = 7: 󹪝le CFG_BEAR.ACX
y = 8: 󹪝le BEARINGTYPE.ACX
y = 9: 󹪝le BRAKE.ACX
y = 10: 󹪝le CFG_BRAKE.ACX
y = 11: 󹪝le ENCODER.ACX
y = 12: 󹪝le CFG_ENCODER.ACX
y = 13: 󹪝le ENCODERGEAR.ACX
y = 14: 󹪝le CFG_ENC_GEAR.ACX
y = 15: 󹪝le LOADGEAR.ACX
y = 16: 󹪝le THERMMOTMOD3.ACX
y = 17: 󹪝le CFG_THERMMOTMOD3.ACX
y = 30: 󹪝le WHITELIST.ACX
Remedy: Correct the 󹪝le involved.
F01018
Runup has been interrupted several times
Message class: Hardware/software error (1)
Message value: -
Component: None
Response: NONE
Acknowledgment: POWER ON
Cause: Module booting was interrupted several times. As a consequence, the module boots with the factory setting.
P
os
sible r
easons f
or boo
ting being interrupted:
- Power supply interrupted.
- CPU crashed.
- Parameterization invalid.
Remedy: - Carry out a POWER ON (switch-o󹪜/switch-on). Aft
er switching on, the module reboots from the valid parameterization (if
available).
- Restore the valid parameterization.
Examples:
a) Carry out a 󹪝rst commissioning, save, carry out a POWER ON (switch-o󹪜/switch-on).
b) Load another valid parameter backup (e.g. from the memory card), save, carry out a POWER ON (switch-o󹪜/switch-on).
Note:
If the fault situation is repeated, then this fault is again output after several interrupted boots.
A01019 Writing to the removable data medium unsuccessful
Message class: Hardware/software error (1)
Message value: -
Component: Control Unit (CU)
Response: NONE
Acknowledgment: NONE