Acknowledgment: IMMEDIATELY
Cause: The maximum permissible number of drive objects of a category was exceeded.
No
te regarding the message value:
The individual information is coded as follows in the message value (r0949/r2124):
ddccbbaa hex:
aa = drive object category:
- Drive object category, for which the maximum permissible number of drive objects was exceeded.
bb = number permitted:
- Maximum permissible number for this drive object category.
cc = actual number:
- Actual number for this drive object category.
dd = no signi󹪝cance
Remedy: - Switch o󹪜 the unit.
- Suitably res
trict the number of drive objects of the speci󹪝ed category by reducing the number of inserted components.
- Re-commission the unit.
F01152 CU: Invalid constellation of drive object types
Message class: Error in the parameterization / con󹪝guration / commissioning procedure (18)
Mes
sage value: -
Component: None
Response: NONE
Acknowledgment: POWER ON
Cause: It is not possible to simultaneously operate drive object types SERVO, VECTOR and HLA.
A maximum of 2 of t
hese drive object types can be operat
ed on a Control Unit.
Remedy: - Switch o󹪜 the unit.
- Restrict the use of dr
ive object types SERVO, VECTOR, HLA to a maximum of 2.
- Re-commission the unit.
F01200 CU: Time slice management internal software error
Message class: Hardware/software error (1)
Message value: %1
Component: Control Unit (CU)
Response: OFF2
Acknowledgment: IMMEDIATELY
Cause: A time slice management error has occurred.
It is pos
sible that the sampling times ha
ve been inadmissibly set.
Fault value (r0949, interpret hexadecimal):
998:
Too many time slices occupied by technology functions (e.g. DCC).
999:
Too many time slices occupied by the basic system. Too many di󹪜erent sampling times may have been set.
Additional values:
Only for internal Siemens troubleshooting.
Remedy: - Contact Technical Support.
F01205 CU: Time slice over󹪞ow
Messag
e class: Hardware/software error (1)
Message value: %1
Component: Control Unit (CU)
System messages
11.3Faults and alarms
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
346 Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA

Table of Contents

Other manuals for Siemens SINAMICS S200

Related product manuals