EasyManua.ls Logo

Siemens SINAMICS S200 - Page 520

Siemens SINAMICS S200
764 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Property Description
Holding brake Optional integrated holding brake
Connection
1FL2102, 1FL2☐03, 1FL2104, 1FL2204:dual-cable connections with a
h
ybrid connector
1FL2☐05:tw
o-cable connections with two angular connectors
1FL23☐☐:three-cable connections with three angular connectors
13.2.2 Permissible environmental conditions for the motor
Technical data
Table 13-12
Environmental conditions for transport
Environmental conditions for transport in the transport packaging according to Class 2K3 to DINENIEC60721‑3‑2,
e
xcept for en
vironmental variables "air temperature" and "condensation"
Climatic environmental conditions
Temperature: ‑15°C … +70°C
Highest relative
humidity: < 90% at 30 °C, condensation not permissible
Mechanical environmental conditions Single shocks (6ms), max. 300 m/s²
Protection against chemical substances Protected according to Class 2C2
Biological environmental conditions Suitable according to Class 2B2
Table 13-13 Environmental conditions for long-term storage
Environmental conditions for long-term storage in the product packaging according to Class 1K3 to
DINENIEC60721‑3‑1, e
xcept for en
vironmental variables "air temperature", "highest relative humidity" and "conden‐
sation"
Climatic environmental conditions
Temperature: -20°C...+65°C
Highest relative
humidity: < 90% at 30 °C, condensation not permissible
Mechanical environmental conditions Vibration-free storage space, v
rms
< 0.2 mm/s
Protection against chemical substances Protected according to Class 1C2
Biological environmental conditions Suitable according to Class 1B2
Duration
Six months for the above-mentioned conditions.
Special preservation measur
es are required for storage periods of six
months up to a maximum of two years.
For more information, please contact your local sales partner.
Technical data
13.2Technical data of the motor
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
518 Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA