Table 13-14 Environmental conditions during operation
Environmental conditions during operation according to 3K4 to DINENIEC60721‑3‑3, except for environmental vari‐
ables "lo
w air temperatur
e", "condensation" and "low air pressure"
Installation altitude Up to 1000 m above sea level without limitations
You can get additional information in Section "Der
ating factors
(Page521)".
Climatic environmental conditions
1)
• Temperature: -15 °C ... +40 °C, power derating at higher temperatures
• Relative humidity: < 90% at 30 °C, condensation not permis
sible
• Absolute air humidity: 1g/m³ ... 29 g/m³
• Rate of temperature change
2)
: 0.5°/min
• Atmospheric pressure: 89kPa
1) 3)
... 106 kPa
4)
• Solar radiation: 700 W/m²
2)
• Movement of the air: 1.0 m/s
• Water (other than rain): see Section "Degree of protection (Page523)"
Mechanical environmental conditions
• Vibration severity grade: A (according to IEC60034‑14:2003)
• Shock resist
ance (m/s
2
):
– 1FL2102, 1FL2☐03, 1FL2104, 1FL2204, 1FL2☐05: 50 (continuous
in axial direction), 50 (continuous in radial direction), 300 (in a short
time of 11 ms)
– 1FL23☐☐: 25 (continuous in axial direction), 50 (continuous in ra‐
dial direction), 300 (in a short time of 11 ms)
Protection against chemical substances Protected according to 3C2 to DIN EN IEC 60721‑3‑3
Biological environmental conditions Suitable according to 3B2 to DIN EN IEC 60721‑3‑3
Pollution Suitable for environments with degree of pollution 2 according to
IEC61800‑5‑1
Cooling air Clean and dry air
The motors are not suitable for operation under the following circumstances:
• In a v
acuum
5)
• In salt-laden or aggressiv
e atmospheres
• Outdoors
1)
Increased ruggedness with r
egard to low air temperature and low atmospheric pressure better than 3K3 according to
DINENIEC60721‑3‑3
2)
Averaged over a period of 5min
3)
The limit value of 89kPa covers applications at altitudes up to 1000m.
4)
Conditions in mines are not considered.
5)
Operation in a vacuum is not permissible because of the low dielectric strength and poor heat dissipation.
Technical data
13.2Technical data of the motor
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA 519