Description: Displays the missing enable signals. All enable signals are required to operate the drive. The enable signals are set by
the control.
Bit array
: Bit Signal name 1 signal 0 signal
00 OFF1 enable missing Yes No
01 OFF2 enable missing Yes No
02 OFF3 enable missing Yes No
03 Operation enable missing Yes No
08 Safety enable missing Yes No
10 Ramp-function generator enable missing Yes No
12 Speed setpoint enable missing Yes No
16 OFF1 enable internal missing Yes No
17 OFF2 enable internal missing Yes No
18 OFF3 enable internal missing Yes No
19 Pulse enable internal missing Yes No
21 STOP2 enable internal missing Yes No
26 Drive inactive or not operational Yes No
28 Brake open missing Yes No
30 Speed controller enable missing Yes No
Dependency: See also: r0002
Appendix
A.3Parameters
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
594 Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA