r0277[0] Power unit heat sink fan wear counter
Data type: FloatingPoint32 Visible in: Extended display
R
ead permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or drive applications
Parame
ter group: Power unit
Unit: %
Description: Displays the wear counter of the heat sink fan in the power unit.
After a fan has been replaced, using an appropr
iate button, the value can be reset in the commissioning tool to 0.
Dependency: See also: A30042
p0290 Power unit overload response
Data type: Integer16 Visible in: Extended display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or drive applications
Can be
changed in the operating
state:
Ready for oper
ation
Parameter group: Power unit
Unit: -
Min:
0
Max:
1
Factory setting:
0
Appendix