p0322[0] Maximum motor speed
Data type: FloatingPoint32 Visible in: Extended display
R
ead permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Can be
changed in the operating
state:
Commissioning
Par
ameter group: Motor data, Quick commissioning
Unit: rpm
Min:
0.0 [rpm]
Max:
210000.0 [rpm]
Factory setting:
0.0 [rpm]
Description: Displays the maximum motor speed.
Dependency: See also: p1082
p0323[0] Maximum motor current
Data type: FloatingPoint32 Visible in: Extended display
R
ead permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Can be
changed in the operating
state:
Commissioning
Par
ameter group: Motor data, Quick commissioning
Unit: Arms
Min:
0.00 [Arms]
Max:
20000.00 [Arms]
Factory setting:
0.00 [Arms]
Description: Displays the maximum permissible motor current.
r0341[0] Motor moment of inertia
Data type: FloatingP
oint32 Visible in: Extended display
R
ead permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Parame
ter group: Motor data, Speed controller
Unit: k
gm²
Description: Displays the motor moment of inertia (without load).
p0400[0] Encoder type selection
Data type: Integer16 Visible in: St
andard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Can be
changed in the operating
state:
Commissioning
Par
ameter group: Motor encoder, Quick commissioning
Unit: -
Min:
0
Max:
10100
Factory setting:
0
Description: Selects the encoder from the list of encoder types supported.
Value: 0: No encoder
801: Digital encoder interface AS17, singleturn
802: Digital encoder interface AS21, singleturn
803: Digital encoder interface AM21, multiturn 4096
9999: User dened
Appendix
A.3Parameters
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2